The Woolich Racing Log Box products allow data to be written (logged) to an micro-SD card while the bike is being run on the street, track or dyno. The Log Box will typically start logging data whenever the ignition is started AND the device is NOT connected to the computer.
The exact settings about how the data logging works can be modified by the user in the
Woolich Racing Tuned software on the computer. These settings can be viewed by connecting the Log Box to your PC and setting your Log Start Configuration which can be found under Tools > Device Configuration Page as shown below.
The Log Start Configuration is shown as in the screenshot below:
The Default "Log Start Configuration" settings are:
Time Delay (secs) = 0
- The number of seconds to delay before starting to log data after the device is powered on. This setting is useful if you would like to delay data logging to prevent log files from being created when starting the bike for short amounts of time.
Engine Running = not ticked
- When this option is checked the engine must be running before data will be logged. This setting is useful to prevent logging data when the key is turned on but the engine is not running.
RPM = 0
- The RPM that the engine must go above before data logging will begin. This setting is useful to delay the start of data logging until the engine has been taken above the selected RPM.
Log data to micro-SD in Engine data Mode = not ticked.
- This setting creates data logs on the Interface when in normal operation mode. It is useful if you are using the Interface on the dyno to monitor engine data and you would also like to log data to be used with the Woolich Racing AutoTune.
OBD2 Engine data = not ticked
- This option is required for models that use OBD2 engine data protocol. You can see it your model requires OBD2 data by checking the Engine Data Type' in the Bin File Details. If your model shows the Engine Data type: "OBD2 - CAN", then you will need to tick this option, and save to the Log Box.
CAN Logging = not ticked
- This is a troubleshooting option that you may be asked to use by the Woolich Racing Support Team. Please do not tick this option unless asked to by one of our Support Technicians.
After making changes to the the Start Log Configuration, be sure to click the Save button so that the settings are written to the Log Box.
If all options set to 0 or unticked, the Log Box will start recording data as soon as power is supplied (ie. when the key is turned).
After the Log Start Configuration has been set, you can disconnect the Log Box from your PC, and connect it to your Bike harness. You should then start the bike engine, and check the LEDs on the Log Box - the green and orange LEDs should flash quickly, and the red one should flash briefly every few seconds. This indicates the Log Box is receiving data, and recording it to the micro-SD Card.
These Support Center articles may also be of interest to you: